SQD LUB12

Page Loading...

Mouse over image to zoom, click to enlarge

DESCRIPTION
TeSys U standard power base, 3 poles (3NO), 12A/690V, to be completed with a control unit LUC to form a TeSys U starter controller, for 3-phase motor applications up to 5.5kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" starter controller with basic or advanced protection and control functions. It is equipped with a control terminal block, and blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Square D (Schneider)  /  LUB12

TeSys U, power base, 12 A, screw clamps control

SQD LUB12 12A POWER BASE

SE Part Number: 30454

UPC:  78590122224

Part Number: LUB12

UNSPSC: 39121521

Status:  STOCK

Country of Origin:  France

Your Price:  $233.16 / ea
 
Qty  eaAdd to Cart View Cart Checkout

INVENTORY / AVAILABILITY

Total Availabile: 33 ea

Availability By Branch

  • Springfield, ILB/O or Special Order
  • Bloomington, ILB/O or Special Order
  • Champaign, ILB/O or Special Order
  • East Peoria, IL1 ea
  • Danville, ILB/O or Special Order
  • Mt. Vernon, ILB/O or Special Order
  • Mattoon, IL14 ea
  • Peru, IL3 ea
  • Rockford, IL2 ea
  • Decatur, IL6 ea
  • Moline, ILB/O or Special Order
  • Carbondale, ILB/O or Special Order
  • Davenport, IAB/O or Special Order
  • Edwardsville, ILB/O or Special Order
  • Decatur - CorporateB/O or Special Order
  • East Peoria - CorporateB/O or Special Order
  • Quincy, IL1 ea
  • Hannibal, MOB/O or Special Order
  • Evansville, IN6 ea
  • Vincennes, INB/O or Special Order
  • Terre Haute, INB/O or Special Order

Offer Sustainability

  • Green Premium Status: Green Premium product
  • EU RoHs Directive: Compliant
  • Mercury Free: Yes
  • WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Environment

  • Heat Dissipation: 2 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.7 W control circuit with LUCM
  • Immunity To Microbreaks: 3 ms
  • Immunity To Voltage Dips: 70 % / 500 ms IEC 61000-4-11
  • Product Certifications: UL || ASEFA || CSA || GOST || ABS || CCC || ATEX || BV || GL || LROS (Lloyds register of shipping) || DNV
  • Standards: UL 508 type E, with phase barrier || EN 60947-6-2 || IEC 60947-6-2 || CSA C22.2 No 14 type E
  • IP Degree Of Protection: IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone)
  • Protective Treatment: TH IEC 60068
  • Ambient Air Temp For Op: -13…140 °F (-25…60 °C) with LUCM || -13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD
  • Ambient Air Temp For Storage: -40…185 °F (-40…85 °C)
  • Fire Resistance: 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 || 1202 °F (650 °C) IEC 60695-2-12
  • Operating Altitude: 6561.68 ft (2000 m)
  • Shock Resistance: 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
  • Vibration Resistance: 2 gn 5…300 Hz) power poles open IEC 60068-2-27 || 4 gn 5…300 Hz) power poles closed IEC 60068-2-27
  • Resist Electrostatic Dischrg: 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
  • Resistance To Radiated Fields: 9.14 V/m (10 V/m) 3 IEC 61000-4-3
  • Resistance To Fast Transients: 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
  • Non-Dissipating Shock Wave: 1 kV serial mode 24...240 V AC IEC 60947-6-2 || 1 kV serial mode 48...220 V DC IEC 60947-6-2 || 2 kV common mode 24...240 V AC IEC 60947-6-2 || 2 kV common mode 48...220 V DC IEC 60947-6-2
  • Imm To Radioelectric Fields: 10 V IEC 61000-4-6

Main

  • Range: TeSys
  • Product Name: TeSys U
  • Device Short Name: LUB
  • Product Or Component Type: Non reversing power base
  • Device Application: Motor
  • Poles Description: 3P
  • Suitability For ISOlation: Yes
  • Ith Cnvtl Free Air Therm Crrt: 12 A
  • Utilisation Category: AC-44 || AC-43 || AC-41
  • [Uc] Control Circuit Voltage: 24 V AC 50/60 Hz || 24 V DC || 48 V AC 50/60 Hz || 48...72 V DC || 110...220 V DC || 110...240 V AC 50/60 Hz

Contractual Warranty

  • Warranty: 18 months

Ordering And Shipping Details

  • Category: 22396 - TESYS U - SELF PRTCTD STARTER (LUB)
  • Discount Schedule: I11
  • GTIN: 00785901222248
  • Package 1 Weight: 0.84 kg (1.86 lb(US))
  • Returnability: Yes
  • Country Of Origin: FR

Complementary

  • Auxiliary Contact Composition: 1 NO + 1 NC
  • Auxiliary Contacts Type: Linked contacts 1 NO + 1 NC) IEC 60947-4-1 || Mirror contact 1 NC) state of the power draft IEC 60947-1
  • Ue Rated Operational Voltage: 230 V || 440 V || 500 V || 690 V
  • Network Frequency: 40...60 Hz
  • Ie Rated Operational Current: 12 A <= 440 V || 12 A 500 V || 9 A 690 V
  • Ics Rated Service Breaking Cap: 10 kA 500 V || 4 kA 690 V || 50 kA 230 V || 50 kA 440 V
  • Typical Current Consumption: 130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 150 mA 24 V DC I maximum while closing with LUCM || 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 35 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 35 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 35 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 35 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 70 mA 24 V DC I rms sealed with LUCM
  • Safety Reliability Level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Operating Time: 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit || 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 75 ms closing with LUCM control circuit
  • Mechanical Durability: 15000000 cycles
  • Operating Rate: 60 cyc/mn
  • Ui Rated Insulation Voltage: 600 V UL 508 || 690 V IEC 60947-1 3) || 600 V CSA C22.2 No 14
  • Uimp Rated Imp Wstd Voltage: 6 kVIEC 60947-6-2
  • Safe Separation Of Circuit: 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
  • Connections - Terminals: Control circuit screw clamp terminals 1 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end || Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end || Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…1.5 mm²) rigid without cable end || Control circuit screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²) flexible with cable end || Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) flexible without cable end || Control circuit screw clamp terminals 2 0.00…0.00 in² (0.75…1.5 mm²) rigid without cable end || Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²) rigid without cable end || Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end || Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) flexible without cable end || Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) flexible with cable end || Power circuit screw clamp terminals 2 0.00…0.01 in² (1…6 mm²) rigid without cable end || Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end
  • Tightening Torque: Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) flat 0.20 in (5 mm) || Control circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Philips no 1 0.20 in (5 mm) || Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) flat 0.24 in (6 mm) || Power circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Philips No 2 0.24 in (6 mm)
  • Width: 1.77 in (45 mm)
  • Height: 6.06 in (154 mm)
  • Depth: 4.96 in (126 mm)
  • Product Weight: 1.98 lb(US) (0.9 kg)

End Of Life Manual

TeSys U Power Base - EoLi (pdf)
TeSys U Power base + Control unit (pdf)
End-of-Life Instructions TeSys U (pdf)

System User Guide

Modicon M340, CANopen, Altivar, Lexium, TeSysU and Preventa (pdf)
Twido and Altivar, Magelis and OTB, FTB (pdf)
Twido and Altivar, Magelis and OTB, FTB (zip)
Twido and Altivar, Magelis and OTB, FTB (pdf)

RoHS Declaration

TeSys U, power base, 12 A, screw clamps control (pdf)

CAD

SCREW CLAMP BASE (zip)
SCREW CLAMP BASE (stp)
Starter-controlers\non-reversing power bases\with phase barrier (dxf)
Starter-controlers\non-reversing power bases\with phase barrier (dwg)
Starter-controlers\non-reversing power bases\with phase barrier (dwf)
Starter-controlers\non-reversing power bases\with phase barrier (wmf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dwg)
Starter-controlers\non-reversing power bases\with Modbus communication module (wmf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dwf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dxf)
Starter-controlers\non-reversing power bases\with multifunction control units (dxf)
Starter-controlers\non-reversing power bases\with multifunction control units (wmf)
Starter-controlers\non-reversing power bases\with multifunction control units (dwf)
Starter-controlers\non-reversing power bases\with multifunction control units (dwg)
Starter-controlers\non-reversing power bases\with phase barrier (dwf)
Starter-controlers\non-reversing power bases\with phase barrier (wmf)
Starter-controlers\non-reversing power bases\with phase barrier (dwg)
Starter-controlers\non-reversing power bases\with phase barrier (dxf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dxf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dwf)
Starter-controlers\non-reversing power bases\with Modbus communication module (wmf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dwg)
Starter-controlers\non-reversing power bases\with multifunction control units (dxf)
Starter-controlers\non-reversing power bases\with multifunction control units (wmf)
Starter-controlers\non-reversing power bases\with multifunction control units (dwf)
Starter-controlers\non-reversing power bases\with multifunction control units (dwg)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dwg)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dxf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dwf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (wmf)
Starter-controlers\non-reversing power bases\with AS-i communication module (dwg)
Starter-controlers\non-reversing power bases\with AS-i communication module (wmf)
Starter-controlers\non-reversing power bases\with AS-i communication module (dwf)
Starter-controlers\non-reversing power bases\with AS-i communication module (dxf)
Starter-controlers\non-reversing power bases\with parallel link module (wmf)
Starter-controlers\non-reversing power bases\with parallel link module (dwf)
Starter-controlers\non-reversing power bases\with parallel link module (dxf)
Starter-controlers\non-reversing power bases\with parallel link module (dwg)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dwg)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dwf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (wmf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dxf)
Starter-controlers\non-reversing power bases\with AS-i communication module (wmf)
Starter-controlers\non-reversing power bases\with AS-i communication module (dwf)
Starter-controlers\non-reversing power bases\with AS-i communication module (dwg)
Starter-controlers\non-reversing power bases\with AS-i communication module (dxf)
Starter-controlers\non-reversing power bases\with parallel link module (dwg)
Starter-controlers\non-reversing power bases\with parallel link module (dwf)
Starter-controlers\non-reversing power bases\with parallel link module (dxf)
Starter-controlers\non-reversing power bases\with parallel link module (wmf)
Starter-controlers\non-reversing power bases\with phase barrier (dxf)
Starter-controlers\non-reversing power bases\with phase barrier (wmf)
Starter-controlers\non-reversing power bases\with phase barrier (dwf)
Starter-controlers\non-reversing power bases\with phase barrier (dwg)
Starter-controlers\non-reversing power bases\with Modbus communication module (dxf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dwf)
Starter-controlers\non-reversing power bases\with Modbus communication module (wmf)
Starter-controlers\non-reversing power bases\with Modbus communication module (dwg)
Starter-controlers\non-reversing power bases\with multifunction control units (wmf)
Starter-controlers\non-reversing power bases\with multifunction control units (dwf)
Starter-controlers\non-reversing power bases\with multifunction control units (dxf)
Starter-controlers\non-reversing power bases\with multifunction control units (dwg)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dwf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (wmf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dxf)
Starter-controlers\non-reversing power bases\with prewired control circuit components (dwg)
Starter-controlers\non-reversing power bases\with AS-i communication module (dxf)
Starter-controlers\non-reversing power bases\with AS-i communication module (wmf)
Starter-controlers\non-reversing power bases\with AS-i communication module (dwg)
Starter-controlers\non-reversing power bases\with AS-i communication module (dwf)
Starter-controlers\non-reversing power bases\with parallel link module (dwg)
Starter-controlers\non-reversing power bases\with parallel link module (dxf)
Starter-controlers\non-reversing power bases\with parallel link module (wmf)
Starter-controlers\non-reversing power bases\with parallel link module (dwf)

REACh Declaration

TeSys U, power base, 12 A, screw clamps control (pdf)

Instruction Sheet

LUB.+LUCA/LUCB/LUCC/LUCD - TeSys U power base + control units (pdf)
Instruction sheet - GV2 MC/MP Enclosures and accessories (pdf)

Declaration Of Conformity

EU Declaration SC16031606C TeSys U (pdf)

Certificate

INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Self-Protecting (pdf)
ATEX TeSys U - TeSys U Atex (pdf)
UL Certificate E164862 NLDX Tesys D TeSys U (pdf)

Handout

TeSys SoLink Handout (pdf)Product Datasheet (pdf)

Product Environmental

TeSys U, power base (pdf)
TeSys U, power base + control unit (pdf)

Catalog

Digest 178 Catalog 18: Contactors and Starters-IEC (pdf)
Tesys catalogue 2019 - 2020 Motor control and protection components (pdf)
TeSys catalogue - 2019 - 2020 - chapter A4 - All-in-one motor starters - TeSys U (pdf)
TeSys™ U-Line Motor Starters (pdf)
 
 
Time Zone 
 

Alternative Product Disclaimer

The online Cross-Reference Information presented on Springfield Electric's Website is proprietary and provided as a tool to determine potential equivalent catalog numbers. Catalog numbers of other manufacturers are shown for products that appear to be equivalent in their functional use, though not necessarily interchangeable. Product replacements/cross-reference may not be exact one-for-one match. They may not be equivalent as to form-fit-function requirements and may require a system replacement . Springfield Electric and the manufacturers recommend review of manufacturers' product literature, associated documentation of product details and verification of the information necessary to make the appropriate product selecting for a given application.